Part Number Hot Search : 
AX315 1100T KA8301L MBR2020 IXDI404P 74456168 2477M002 LF2250
Product Description
Full Text Search
 

To Download 2902005 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 1 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) configurable namur signal conditioner with plug-in connection technology for proximity sensors, floating switch contacts, and switch contacts with resistance circuit. 2 transistor outputs. configurable via dip switch. push-in connection technology. product description configurable namur 4-way signal conditioner with plug-in connection technology for operating proximity sensors according to en 60947-5-6, floating switch contacts, and switch contacts with resistance circuit. two transistor outputs are available on the output side. the second output can be used either for duplicating signals or for signaling faults on the sensor line. you can configure the signal conditioner via dip switches. the device supports fault monitoring and nfc communication. why buy this product ?floating contacts and contacts with resistance circuit can be connected ?power supply possible via the foot element (tbus) ?highly compact isolation amplifier for electrical isolation, amplification, and duplication of proximity sensor signals ?for proximity sensors according to iec 60947-5-6 and en 50227 ?second output can be used as a duplicator or error signaling output ?error indication via diagnostic led and analog signal ?n/o contacts at output ?input and output signals can be configured via dip switches ?3-way isolation key commercial data packing unit 1 stk weight per piece (excluding packing) 100.000 g custom tariff number 85437090 country of origin germany technical data note di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 2 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 technical data note utilization restriction emc: class a product, see manufacturer's declaration in the download area dimensions width 6.2 mm height 110.5 mm depth 120.5 mm ambient conditions ambient temperature (operation) -40 c ... 70 c ambient temperature (storage/transport) -40 c ... 85 c degree of protection ip20 power supply nominal supply voltage 24 v dc supply voltage range 9.6 v dc ... 30 v dc (the din rail bus connector (me 6,2 tbus-2 1,5/5- st-3,81 gn, order no. 2869728) can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en?60715)) typical current consumption 18 ma (24 v dc) 35 ma (12 v dc) power consumption 450 mw (9.6 v dc) connection data connection method push-in connection single conductor/terminal point, solid, with ferrule, min. 0.14 mm2 single conductor/terminal point, solid, with ferrule, max. 2.50 mm2 single conductor/terminal point, solid, without ferrule, min. 0.14 mm2 single conductor/terminal point, solid, without ferrule, max. 2.50 mm2 conductor cross section flexible min. 0.14 mm2 conductor cross section flexible max. 2.5 mm2 min. awg conductor cross section, flexible 24 max. awg conductor cross section, flexible 12 stripping length 10 mm general no. of channels 1 status display yellow led (switching output) yellow led (switching output) electrical isolation reinforced insulation in accordance with iec 61010-1 overvoltage category ii degree of pollution 2 di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 3 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 technical data general rated insulation voltage 300 v (effective) test voltage, input/output/supply 3 kv (50 hz, 1 min.) electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 noise immunity en 61000-6-2 when being exposed to interference, there may be minimal deviations. color gray housing material pbt mounting position any assembly instructions the t connector can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en 60715. conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t6 class i, zone 2, group iic t6 gl gl applied for emc data designation electromagnetic rf field standards/regulations en 61000-4-3 designation fast transients (burst) standards/regulations en 61000-4-4 designation conducted interferences standards/regulations en?61000-4-6 standards and regulations electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 standards/regulations en 61000-4-2 designation electromagnetic rf field standards/regulations en 61000-4-3 en 61000-4-4 en 61000-4-5 designation conducted interferences standards/regulations en?61000-4-6 electrical isolation reinforced insulation in accordance with iec 61010-1 conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 4 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 technical data standards and regulations ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t6 class i, zone 2, group iic t6 gl gl applied for drawings pictogram block diagram pictogram classifications ecl@ss ecl@ss 4.0 27210120 ecl@ss 4.1 27210120 di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 5 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 classifications ecl@ss ecl@ss 5.0 27210120 ecl@ss 5.1 27210120 ecl@ss 6.0 27210120 ecl@ss 7.0 27210120 ecl@ss 8.0 27210121 ecl@ss 9.0 27210121 etim etim 3.0 ec001485 etim 4.0 ec001446 etim 5.0 ec001485 unspsc unspsc 6.01 30211506 unspsc 7.0901 39121008 unspsc 11 39121008 unspsc 12.01 39121008 unspsc 13.2 39121008 approvals approvals approvals ul listed / cul listed / culus listed ex approvals ul listed / cul listed / culus listed approval details ul listed? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 6 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 approvals cul listed? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 culus listed? ? accessories accessories device marking marker for end clamp?-?uct-em (30x5)?-?0801505 marker for end clamp, sheet, white, unlabeled, can be labeled with: thermomark card, bluemark cled, bluemark led, topmark laser, mounting type: snapped into marker carrier, lettering field: 30 x 5 mm ? ? marker for end clamp?-?uct-em (30x5) ye?-?0830340 marker for end clamp, sheet, yellow, unlabeled, can be labeled with: thermomark card, bluemark cled, bluemark led, topmark laser, mounting type: snapped into marker carrier, lettering field: 30 x 5 mm ? ? plastic label?-?uc-emlp (15x5)?-?0819301 plastic label, sheet, white, unlabeled, can be labeled with: bluemark cled, bluemark led, plotter, mounting type: adhesive, lettering field: 15 x 5 mm ? ? di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 7 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 accessories plastic label?-?uc-emlp (15x5) ye?-?0822615 plastic label, sheet, yellow, unlabeled, can be labeled with: bluemark cled, bluemark led, plotter, mounting type: adhesive, lettering field: 15 x 5 mm ? ? plastic label?-?uc-emlp (15x5) sr?-?0828095 plastic label, sheet, silver, unlabeled, can be labeled with: bluemark cled, bluemark led, plotter, mounting type: adhesive, lettering field: 15 x 5 mm ? ? din rail connector din rail bus connectors?-?me 6,2 tbus-2 1,5/5-st-3,81 gn?-?2869728 din rail connector for din rail mounting. universal for tbus housing. gold-plated contacts, 5-pos. ? ? evaluation unit monitoring module?-?mini mcr-2-fm-rc?-?2904504 fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the fm system and for monitoring the supply voltages. error reporting via n/o contact. screw connection technology, standard configuration ? ? monitoring module?-?mini mcr-2-fm-rc-pt?-?2904508 fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the fm system and for monitoring the supply voltages. error reporting via n/o contact. push-in connection technology, standard configuration ? ? di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 8 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 accessories labeled device marker marker for end clamp?-?uct-em (30x5) cus?-?0801589 marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field: 30 x 5 mm ? ? marker for end clamp?-?uct-em (30x5) ye cus?-?0830348 marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field: 30 x 5 mm ? ? plastic label?-?uc-emlp (15x5) cus?-?0824550 plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field: 15 x 5 mm ? ? plastic label?-?uc-emlp (15x5) ye cus?-?0824551 plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field: 15 x 5 mm ? ? plastic label?-?uc-emlp (15x5) sr cus?-?0828099 plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field: 15 x 5 mm ? ? di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 9 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 accessories power module power terminal block?-?mini mcr-2-ptb?-?2902066 power terminal with plug-in connection technology for delivering the supply voltage to the din rail connector. monitoring of the supply voltages in combination with the fault monitoring module. screw connection technology ? ? power terminal block?-?mini mcr-2-ptb-pt?-?2902067 power terminal with plug-in connection technology for delivering the supply voltage to the din rail connector. monitoring of the supply voltages in combination with the fault monitoring module. push-in connection technology ? ? power supply power supply unit?-?mini-sys-ps-100-240ac/24dc/1.5?-?2866983 primary-switched mini power supply for din rail mounting, input: 1-phase, output: 24 v dc/1.5 a ? ? terminal marking marker strip?-?sk 5,0 wh:reel?-?0805221 marker strip, roll, white, unlabeled, can be labeled with: thermomark roll, thermomark x, thermomark s1.1, thermomark roll x1, mounting type: adhesive, lettering field: continuous x 5 mm ? ? di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm
https://www.phoenixcontact.com/us/products/2902005 09/06/2016???page? 10 ?/? 10 isolation amplifier?-?mini mcr-2-nam-2ro-pt?-?2902005 accessories din rail bus connectors?-?me 6,2 tbus-2 1,5/5-st-3,81 gy?-?2695439 din rail connector (tbus), 5-pos., for bridging the supply voltage, can be snapped onto ns 35/... din rails according to en?60715 ? ? phoenix contact 2016 ? - all rights reserved http://www.phoenixcontact.com di1di2 in sensor / field out plc / dcs 5 3 6 4 1 1 1 2 2 2 + + C C C 1 2 6 4 out 1C in + inC out 1+ + C 7 8 5 + 3 fm out 2+ out 2- pwr+ pwr+ pwrC pwrC ii 3 gex na iic t4 gc x power out in fm


▲Up To Search▲   

 
Price & Availability of 2902005

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X